Skip to main content

Table 2 Acquisition parameters for MR imaging

From: Acidosis-mediated increase in IFN-γ-induced PD-L1 expression on cancer cells as an immune escape mechanism in solid tumors

 

T1 FLASH

T2 TurboRARE

cestFISP

TE

2.670 ms

33.580 ms

1.435 ms

TR

100 ms

5551.773 ms

2.870 ms

Flip angle

30.0°

-

30.0°

Spatial resolution

0.43 × 0.43

0.3 × 0.3 mm2

0.6 × 0.6 mm2

Matrix size

256 × 256

128 × 128

64 × 64

FOV

110 × 100 mm2

38.4 × 38.4 mm2

38.4 × 38.4 mm2

Slice thickness

1 mm

1 mm

1 mm

Slice orientation

Coronal

Axial

Axial

Number of averages

1

1

1

Number of repetitions

1

1

 

Number of CEST spectra

-

-

4 preinjection, 6 postinjection

Saturation power

-

-

3 µT

Saturation pulses (pulse duration)

-

-

60 (100 ms)

Number of saturation frequencies

-

-

40

Saturation frequency range (increments), Hz

-

-

-30000

-4500 to -3600 (900)

-3600 to 0 (600)

0 to 2100 (75)

2100 to 2700 (600)

2700 to 4500 (900)

Total acquisition time

12 s 800 ms

1 min 28 s 828 ms

44 min 22 s